Volume 44, Issue 2 , Pages 153-157, June 2005
Novel Technique for Safe Primary Trocar Insertion in Laparoscopy: Chou's Method
Article Outline
Summary
Objective
To report a novel method to minimize major vascular injury during laparoscopic entry and to audit its safety.
Materials and Methods
A novel method (Chou's method) for primary insertion of a reusable conical trocar was applied at a tertiary-referral medical center in a cohort study of women undergoing laparoscopic surgery for gynecologic indications between March 1991 and March 2004. This method uses the unique concept of directly holding the fascia. Complications related to primary trocar insertion, including vascular and visceral injury, were audited.
Results
A consecutive series of 2,963 laparoscopic surgeries performed by the author was studied. No major vascular injury, fascial dehiscence, or hernia was encountered. Two entries failed due to inability to ensure an intraperitoneal location of the trocar because of extensive adhesions; these operations were converted to laparotomy. Eight serosal abrasion injuries of the intestines (0.27%) in severe adhesion cases and one abrasional injury to the gastric serosa (0.034%) were encountered, but fortunately none were severe and all patients recovered uneventfully without repair.
Conclusion
The results with this novel method incorporating the unique concept of directly holding the fascia suggest it to be relatively safe, simple, and economic. The risk of major vascular injury was decreased to nil by this technique and the chance of visceral injury was also minimal.
Key Words: laparoscopy , major vascular injury , primary laparoscopic entry , trocar insertion
No full text is available. To read the body of this article, please view the PDF online.
References
- . How to prevent complications of open laparoscopy . J Reprod Med . 1985;30:660–663
- . Serious trocar accidents in laparoscopic surgery: a French survey of 103,852 operations . Surg Laparosc Endosc . 1996;6:367–370
- . Major and minor injuries during the creation of pneumoperitoneum. A multicenter study on 12919 cases . Surg Endosc . 2001;15:566–569
- . Major vascular injury during gynecologic laparoscopy. Report of a case and review of published cases . Acta Obstet Gynecol Scand . 1989;68:283–285
- . Major vascular injuries during laparoscopic procedures . Am J Surg . 1995;169:543–545
- Trocar injuries in laparoscopic surgery . J Am Coll Surg . 2001;192:677–683
- Complications associated with optical access laparoscopic trocars . Obstet Gynecol . 2002;99:553–555
- . Use of the Hasson cannula producing major vascular injury at laparoscopy . Surg Endosc . 1999;13:1238–1240
- . Blunt Hasson trocar injury: long intra-abdominal trocar and lean patient – a dangerous combination . J Laparoendosc Adv Surg Tech A . 2001;11:259–262
- . The relationship of the umbilicus to the aortic bifurcation: implications for laparoscopic technique . Obstet Gynecol . 1992;80:48–51
- . Injuries to major blood vessels during endoscopy . J Am Assoc Gynecol Laparosc . 1997;4:395–398
- . Risks and prophylaxis in laparoscopy: a survey of 100000 cases . J Reprod Med . 1977;18:269–272
- . A randomized comparison of Veress needle and direct trocar insertion for laparoscopy . Surg Gynecol Obstet . 1993;177:259–262
- . The safety of laparoscopy performed by direct trocar insertion and carbon dioxide insufflation under vision . Aust NZ J Obstet Gynaecol . 1997;37:216–219
- . Direct trocar insertion vs. Veress needle use for laparoscopic sterilization . J Reprod Med . 1990;35:891–894
- . Major vascular injuries during gynecologic laparoscopy . J Am Coll Surg . 1998;186:604–605
- Laparoscopic surgery complications associated with trocar tip design: review of literature and own results . J Laparoendosc Adv Surg Tech A . 1999;9:135–140
- . Incision characteristics associated with six laparoscopic trocar-cannula systems: a randomized, observer-blinded comparison . Obstet Gynecol . 1999;94:89–93
- A randomized prospective study of radially expanding trocars in laparoscopic surgery . J Gastrointest Surg . 2000;4:392–397
- . Pneumoperitoneum needle and trocar injuries in laparoscopy. A survey on possible contributing factors and prevention . J Reprod Med . 1990;35:485–490
- . Laparoscopy without trocars . Surg Endosc . 1997;11:815–818
- . Endoscopic threaded imaging port (EndoTIP) for laparoscopy: experience with different body weights . Obes Surg . 1999;9:44–47
- . Intraabdominal pressure and incision parameters associated with a pyramidal laparoscopic trocar-cannula system and the EndoTIP cannula . J Am Assoc Gynecol Laparosc . 2002;9:508–513
- . A modified instrument and method for laparoscopy . Am J Obstet Gynecol . 1971;110:886–887
- . Laparotomy versus laparoscopy . Prog Clin Biol Res . 1990;358:35–44
PII: S1028-4559(09)60128-5
doi:10.1016/S1028-4559(09)60128-5
© 2005 Taiwan Association of Obstetric & Gynecology. Published by Elsevier Inc. All rights reserved.
Volume 44, Issue 2 , Pages 153-157, June 2005