« Previous
Next »
Taiwanese Journal of Obstetrics and Gynecology
Volume 44, Issue 2
, Pages 153-157
, June 2005
Novel Technique for Safe Primary Trocar Insertion in Laparoscopy: Chou's Method
References
- . How to prevent complications of open laparoscopy . J Reprod Med . 1985;30:660–663
- . Serious trocar accidents in laparoscopic surgery: a French survey of 103,852 operations . Surg Laparosc Endosc . 1996;6:367–370
- . Major and minor injuries during the creation of pneumoperitoneum. A multicenter study on 12919 cases . Surg Endosc . 2001;15:566–569
- . Major vascular injury during gynecologic laparoscopy. Report of a case and review of published cases . Acta Obstet Gynecol Scand . 1989;68:283–285
- . Major vascular injuries during laparoscopic procedures . Am J Surg . 1995;169:543–545
- Trocar injuries in laparoscopic surgery . J Am Coll Surg . 2001;192:677–683
- Complications associated with optical access laparoscopic trocars . Obstet Gynecol . 2002;99:553–555
- . Use of the Hasson cannula producing major vascular injury at laparoscopy . Surg Endosc . 1999;13:1238–1240
- . Blunt Hasson trocar injury: long intra-abdominal trocar and lean patient – a dangerous combination . J Laparoendosc Adv Surg Tech A . 2001;11:259–262
- . The relationship of the umbilicus to the aortic bifurcation: implications for laparoscopic technique . Obstet Gynecol . 1992;80:48–51
- . Injuries to major blood vessels during endoscopy . J Am Assoc Gynecol Laparosc . 1997;4:395–398
- . Risks and prophylaxis in laparoscopy: a survey of 100000 cases . J Reprod Med . 1977;18:269–272
- . A randomized comparison of Veress needle and direct trocar insertion for laparoscopy . Surg Gynecol Obstet . 1993;177:259–262
-
.
The safety of laparoscopy performed by direct trocar insertion and carbon dioxide insufflation under vision
.
Aust NZ J Obstet Gynaecol
. 1997;37:216–219
- . Direct trocar insertion vs. Veress needle use for laparoscopic sterilization . J Reprod Med . 1990;35:891–894
- . Major vascular injuries during gynecologic laparoscopy . J Am Coll Surg . 1998;186:604–605
- Laparoscopic surgery complications associated with trocar tip design: review of literature and own results . J Laparoendosc Adv Surg Tech A . 1999;9:135–140
- . Incision characteristics associated with six laparoscopic trocar-cannula systems: a randomized, observer-blinded comparison . Obstet Gynecol . 1999;94:89–93
- A randomized prospective study of radially expanding trocars in laparoscopic surgery . J Gastrointest Surg . 2000;4:392–397
- . Pneumoperitoneum needle and trocar injuries in laparoscopy. A survey on possible contributing factors and prevention . J Reprod Med . 1990;35:485–490
- . Laparoscopy without trocars . Surg Endosc . 1997;11:815–818
- . Endoscopic threaded imaging port (EndoTIP) for laparoscopy: experience with different body weights . Obes Surg . 1999;9:44–47
- . Intraabdominal pressure and incision parameters associated with a pyramidal laparoscopic trocar-cannula system and the EndoTIP cannula . J Am Assoc Gynecol Laparosc . 2002;9:508–513
- . A modified instrument and method for laparoscopy . Am J Obstet Gynecol . 1971;110:886–887
- . Laparotomy versus laparoscopy . Prog Clin Biol Res . 1990;358:35–44
PII: S1028-4559(09)60128-5
doi: 10.1016/S1028-4559(09)60128-5
© 2005 Taiwan Association of Obstetric & Gynecology. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Taiwanese Journal of Obstetrics and Gynecology
Volume 44, Issue 2
, Pages 153-157
, June 2005
